Chapter 2 PLANNING MCQs 21 min Score: 0 Attempted: 0/21 Subscribe 1. . The active power of a 56” ceiling fan is (A) 80W (B) 100W (C) 150W (D) 200WShow All Answers 2. . What are the names of pins of 3 pin socket (A) N, L, E (B) T, S, R (C) R, Y, B (D) allShow All Answers 3. . In a room the number of fans depends on (A) Size of fan (B) Size of ventilation (C) Size of room (D) a & cShow All Answers 4. . The points considered during planning and design of electrical installations (A) Load calculation (B) All (C) Size of cable (D) Wiring selectionShow All Answers 5. . The points considered during design of electrical installation; (A) Safety rules (B) Availability of accessories (C) Labour required (D) AllShow All Answers 6. . The minimum size of cable for a power circuit is (A) 7/0.044” (B) 7/0.036” (C) 3/0.029” (D) 7/0.029”Show All Answers 7. . How many number of 5A sockets can be used on 15A sub-circuit (A) 2 (B) 5 (C) 4 (D) 3Show All Answers 8. . The ceiling fan is placed at least height of (A) 2m (B) 2.5m (C) 2.75m (D) 3mShow All Answers 9. . In a sub-circuit, the maximum load of incandescent lamps can be (A) 800W (B) 600W (C) 500W (D) 100WShow All Answers 10. . The allowable voltage drop of a cable are (A) 2% (B) 3% (C) 5% (D) 2.5%Show All Answers 11. . In a multistory building, The main distribution board must be placed at (A) Ground floor (B) First floor (C) Top floor (D) Any whereShow All Answers 12. . According to I.E.E.E. the load of a final sub-circuit must not increase from (A) 15A (B) 10A (C) 20A (D) 25AShow All Answers 13. . If load current is greater than rated current of a cable then voltage drop will be (A) Normal (B) All (C) Lesser (D) HigherShow All Answers 14. . The factors considered for selecting a cable for a motor (A) Full load current (B) Length of circuit (C) All (D) TemperatureShow All Answers 15. . According to electricity rules the part must be earthed (A) Metallic cover (B) Metallic pipes (C) a & b (D) Plastic coversShow All Answers 16. . According to I.E.E.E. regulation D-1 (A) Neutral must be earthed (B) Protection from leakage current (C) Protection of machines (D) Protection of workerShow All Answers 17. . The regulation not implemented on isolated metallic parts (A) D-2 (B) D-5 (C) D-4 (D) D-3Show All Answers 18. . According to 54 electricity rule, this must be earthed (A) Metallic casings (B) All (C) Neutral (D) Motors & generatorsShow All Answers 19. . At the time of installation, light wiring and power wiring must be (A) Same circuit (B) Separate circuit (C) a & b (D) None of theseShow All Answers 20. . The load factor of a cable is always (A) Always 1 (B) 1 or less than 1 (C) 1 or less than 1 (D) Always greater than 1Show All Answers 21. . If declared supply voltages are 220V, the permissible voltage drop of a cable will be; (A) 2% (B) 1.25% (C) 3.5% (D) 2.5%Show All Answers