Chapter 2 PLANNING MCQs

1. . The active power of a 56” ceiling fan is

(A) 80W


(B) 100W


(C) 150W


(D) 200W




2. . What are the names of pins of 3 pin socket

(A) N, L, E


(B) T, S, R


(C) R, Y, B


(D) all




3. . In a room the number of fans depends on

(A) Size of fan


(B) Size of ventilation


(C) Size of room


(D) a & c




4. . The points considered during planning and design of electrical installations

(A) Load calculation


(B) All


(C) Size of cable


(D) Wiring selection




5. . The points considered during design of electrical installation;

(A) Safety rules


(B) Availability of accessories


(C) Labour required


(D) All




6. . The minimum size of cable for a power circuit is

(A) 7/0.044”


(B) 7/0.036”


(C) 3/0.029”


(D) 7/0.029”




7. . How many number of 5A sockets can be used on 15A sub-circuit

(A) 2


(B) 5


(C) 4


(D) 3




8. . The ceiling fan is placed at least height of

(A) 2m


(B) 2.5m


(C) 2.75m


(D) 3m




9. . In a sub-circuit, the maximum load of incandescent lamps can be

(A) 800W


(B) 600W


(C) 500W


(D) 100W




10. . The allowable voltage drop of a cable are

(A) 2%


(B) 3%


(C) 5%


(D) 2.5%




11. . In a multistory building, The main distribution board must be placed at

(A) Ground floor


(B) First floor


(C) Top floor


(D) Any where




12. . According to I.E.E.E. the load of a final sub-circuit must not increase from

(A) 15A


(B) 10A


(C) 20A


(D) 25A




13. . If load current is greater than rated current of a cable then voltage drop will be

(A) Normal


(B) All


(C) Lesser


(D) Higher




14. . The factors considered for selecting a cable for a motor

(A) Full load current


(B) Length of circuit


(C) All


(D) Temperature




15. . According to electricity rules the part must be earthed

(A) Metallic cover


(B) Metallic pipes


(C) a & b


(D) Plastic covers




16. . According to I.E.E.E. regulation D-1

(A) Neutral must be earthed


(B) Protection from leakage current


(C) Protection of machines


(D) Protection of worker




17. . The regulation not implemented on isolated metallic parts

(A) D-2


(B) D-5


(C) D-4


(D) D-3




18. . According to 54 electricity rule, this must be earthed

(A) Metallic casings


(B) All


(C) Neutral


(D) Motors & generators




19. . At the time of installation, light wiring and power wiring must be

(A) Same circuit


(B) Separate circuit


(C) a & b


(D) None of these




20. . The load factor of a cable is always

(A) Always 1


(B) 1 or less than 1


(C) 1 or less than 1


(D) Always greater than 1




21. . If declared supply voltages are 220V, the permissible voltage drop of a cable will be;

(A) 2%


(B) 1.25%


(C) 3.5%


(D) 2.5%