Chapter 19 LEVEL MCQs 41 min Score: 0 Attempted: 0/41 Subscribe 1. . Dipsticks are used for the ____________ measurement. (A) Pressure (B) Level (C) Density (D) FlowShow All Answers 2. . The gauge on a tank provides an indication of level at all times. What category of level measurement would you say it represents? (A) Resistive (B) Multipoint (C) Continuous (D) ConductiveShow All Answers 3. . The gauge mounted at the bottom of a tank relies on hydrostatic pressure to provide a level indication. What type of level measurement device is it? (A) Direct (B) Conductive (C) Indirect (D) MultipointShow All Answers 4. . Which of these terms is defined as the position of the surface of a liquid or a solid above or below a fixed reference point? (A) Pressure (B) Level (C) Volume (D) Zero pointShow All Answers 5. . Which of these direct level measurement devices has a weight attached to the end of a reel of flexible measuring tape? (A) Float and cable (B) Resistance tape (C) Conductivity probe (D) Plumb bobShow All Answers 6. . The pipe in a bubbler system is open at the bottom, but connected at the top to a pressure-sensitive gauge and ____________. (A) A similar tank (B) A suction device (C) A regulated air supply (D) An orifice plateShow All Answers 7. . The level of a liquid under pressure can be determined using ____________. (A) Bubbler system (B) Differential pressure manometer (C) Diaphragm box system (D) Air-trap systemShow All Answers 8. . Which of the following level-measurement technologies cannot be adapted to measure solid (powder) level in a vessel? (A) Displacer (B) Float and tape (C) Ultrasonic (D) RadarShow All Answers 9. . Process level measurement is important because of ____________. (A) Inventory management (B) Process safety (C) Consistent supply (D) All theseShow All Answers 10. . To indicate the presence or absence of a liquid or solid at some point is known as _____________ level measurement. (A) Continuous (B) Point (C) Direct (D) IndirectShow All Answers 11. . The measurement of the fluid level over a continuous range is known as ________ level measurement. (A) Continuous (B) Point (C) Direct (D) IndirectShow All Answers 12. . Capacitance probe is a ____________ level measuring instrument. (A) Continuous (B) Point (C) Direct (D) All theseShow All Answers 13. . Float operated level measurement devices are ____________ type instruments. (A) Indirect (B) Pressure sensing (C) Direct (D) PneumaticShow All Answers 14. . Which of the following conversions take place in float element? (A) Level to force (B) Level to voltage (C) Level to displacement (D) None of the mentionedShow All Answers 15. . In displacement type level measurement, which law is used? (A) Charles law (B) Ohms law (C) Faraday's law (D) Archimedes principleShow All Answers 16. . A level gauge uses buoyant force to measure liquid level on a nearly stationary object called a ____________. (A) Pressure gauge (B) Displacer (C) Placer (D) FloatShow All Answers 17. . In displacer a force measuring mechanism senses changes in the buoyant force and converts this force into an ____________. (A) Indication of Level (B) Indication of pressure (C) Indication of force (D) Indication of flowShow All Answers 18. . The amount of pointer rotation depends on the _______ of the displacer. (A) Size (B) Shape (C) Weight (D) All of theseShow All Answers 19. . The displacer gauge can be modified to use with a different liquid by replacing the displacer with one of a different ____________. (A) Diameter (B) Color (C) Material (D) All theseShow All Answers 20. . For less dense liquid the _________ of the displacer is required. (A) Smaller diameter (B) Greater diameter (C) Smaller pipe size (D) Smaller the weightShow All Answers 21. . A sight glass is also called _________ glass. (A) Indicator (B) Hollow (C) Level (D) GaugeShow All Answers 22. . The principle of the Reflex Glass is based on the difference in the ________ of liquid and gas or in particular of water and steam. (A) Deflection (B) Viscosity (C) Movement (D) Refractive indicesShow All Answers 23. . The main disadvantage of using gauge glass is that it is read _________. (A) At remote location (B) On Computer (C) At tank location (D) In control roomShow All Answers 24. . Refraction gauge is based on the principle of _________. (A) Deflection (B) Refraction (C) Movement (D) ReflectionShow All Answers 25. . Light is bent, or refracted, to a greater extent in water than in __________. (A) Steam (B) Oil (C) Solid (D) All of theseShow All Answers 26. . In float level measurement float rests __________________ and follows the changing level of liquid. (A) On the surface of liquid (B) At the bottom of the tank (C) In the middle of the tank (D) At the top of the tankShow All Answers 27. . A floating body would always follow the varying liquid level because of its _________ (A) Weigh (B) Shape (C) Material (D) BuoyancyShow All Answers 28. . The top of the float is usually made _________ so that any solid suspensions in the liquid do not settle on the float and change its weight. (A) Straight (B) Sloping (C) Hollow (D) BendedShow All Answers 29. . As the level rises the apparent weight of the displacer _________. (A) Decreases (B) Increases (C) Remains same (D) DoublesShow All Answers 30. . A liquid in a tank at rest exerts a force on the walls of the tank. This force in a liquid at rest, is known as _________. (A) Atmospheric pressure (B) Differential pressure (C) Static pressure (D) Hydrostatic pressureShow All Answers 31. . Hydrostatic pressure is proportional to the ________ of liquid in the tank. (A) Pressure (B) Height (C) Viscosity (D) VolumeShow All Answers 32. . In open tank level measurement, the lower leg of the DP detector is _________. (A) Connected to the bottom of tank (B) Connected to the top of tank (C) Connected to the middle of tank (D) Vented in airShow All Answers 33. . Conductivity probes operates on the principle that most liquids _______. (A) Are Viscous (B) Conduct electricity (C) Have thermal properties (D) Resist electricityShow All Answers 34. . An air purge system consists of a hollow tube known as _________ inserted in the liquid of the tank. (A) Capillary tube (B) Doppler tube (C) Torque tube (D) Bubbler tubeShow All Answers 35. . The pressure gauge connected to the air purge system is calibrated in terms of liquid _________. (A) Level (B) Pressure (C) Density (D) FlowShow All Answers 36. . In bubbler system when there is no liquid in the tank, the pressure gauge indicate _________. (A) Zero (B) 100 (C) 50 (D) 75Show All Answers 37. . The speed of ultrasonic waves in air at 0 °C is ________ meter/second. (A) 231 (B) 331 (C) 431 (D) 531Show All Answers 38. . The velocity of sound is proportional to the square root of ________. (A) Density (B) Level (C) Temperature (D) ForceShow All Answers 39. . When the level of tank raises, the capacitance of probe varies due to change _________. (A) In dielectric (B) In plate size (C) In plate material (D) All of theseShow All Answers 40. . Which one of the following is not a level measuring instrument? (A) Displacer (B) Sight glass (C) Dipstick (D) ThermocoupleShow All Answers 41. . Which one of the following is not an indirect level measuring instrument? (A) Sight glass (B) Bubbler tube (C) Ultrasonic sensor (D) Conductivity probeShow All Answers