1. The main purpose of electrical equipment maintenance is to:

(A) Ensure reliability and prolong equipment life


(B) Reduce load


(C) Increase voltage


(D) Reduce generation



2. Preventive maintenance is carried out:

(A) Randomly


(B) Only after a breakdown


(C) Only during emergencies


(D) At regular intervals regardless of equipment condition



3. Corrective maintenance is performed:

(A) After a fault or breakdown


(B) Periodically


(C) Before commissioning


(D) During inspection only



4. The main tool used for insulation resistance testing is:

(A) Megger


(B) Voltmeter


(C) Ammeter


(D) Clamp meter



5. Insulation resistance should be measured:

(A) Only after a fault


(B) Only during installation


(C) Regularly to detect deterioration


(D) Randomly



6. The insulation resistance of motor windings should be:

(A) Above 1 MΩ for safe operation


(B) Below 0.1 MΩ


(C) Zero


(D) 100 Ω



7. The primary cause of motor failure is:

(A) Low current


(B) Excess voltage only


(C) Insulation breakdown


(D) Short circuit in line



8. Bearings in electrical machines should be lubricated:

(A) Periodically to reduce friction


(B) Only once during installation


(C) Not required


(D) Continuously without intervals



9. Vibration in motors indicates:

(A) Misalignment, loose parts, or worn bearings


(B) Normal operation


(C) Low voltage only


(D) High frequency only



10. A thermal overload relay protects a motor against:

(A) Short circuits only


(B) Excessive current over time


(C) Low voltage only


(D) Phase reversal only



11. Overcurrent protection is provided by:

(A) Fuses and circuit breakers


(B) Switches only


(C) Transformers only


(D) Insulators



12. Core cleaning of transformers prevents:

(A) Frequency variation


(B) Voltage rise


(C) Overheating and loss of efficiency


(D) Short circuit



13. The purpose of dielectric testing in transformers is to:

(A) Check insulation strength


(B) Check winding resistance


(C) Check voltage


(D) Measure current



14. Regular maintenance of circuit breakers ensures:

(A) Reduced power factor


(B) Increased voltage


(C) Proper operation during faults


(D) Reduced load only



15. In DC machines, commutators should be:

(A) Smooth and clean for proper current flow


(B) Rough


(C) Left dirty


(D) Not connected



16. Brushes of DC machines should be:

(A) Painted


(B) Left loose


(C) Properly seated and lubricated


(D) Removed



17. A megger test is performed at:

(A) Rated voltage or as per manufacturer specification


(B) Zero voltage


(C) Half rated voltage


(D) Twice rated voltage only



18. Thermographic inspection helps to detect:

(A) Phase reversal


(B) Voltage fluctuation


(C) Load variations


(D) Hot spots and overloaded connections



19. In preventive maintenance, check sheets include:

(A) Insulation resistance, lubrication, tightness of connections


(B) Voltage only


(C) Current only


(D) Frequency only



20. Motors showing unusual noise should be:

(A) Stopped and inspected for mechanical faults


(B) Left running


(C) Reconnected immediately


(D) Increased load



21. Oil in transformers should be tested for:

(A) Viscosity only


(B) Dielectric strength and moisture content


(C) Color only


(D) Smell only



22. The main cause of transformer failure is:

(A) Insulation breakdown and overloading


(B) Low frequency


(C) High voltage only


(D) Low voltage only



23. In induction motors, rotor maintenance includes:

(A) Checking for broken bars or loose connections


(B) Only insulation


(C) Only bearings


(D) Only winding



24. Surge protection devices protect equipment against:

(A) Frequency variation


(B) Overcurrent only


(C) Low voltage only


(D) Overvoltage and lightning surges



25. Electrical connections should be:

(A) Tight and free from corrosion


(B) Loose for flexibility


(C) Painted


(D) Not important



26. Insulators should be checked for:

(A) Cracks, contamination, and deterioration


(B) Color only


(C) Voltage only


(D) Frequency only



27. Periodic testing of protective relays ensures:

(A) Increased voltage


(B) Correct operation during faults


(C) Reduced load


(D) Reduced efficiency



28. Overheating in motors is mainly caused by:

(A) Overload, low voltage, or poor ventilation


(B) Proper load


(C) High efficiency


(D) Low resistance



29. Insulation in cables should be:

(A) Painted


(B) Left as is


(C) Free from cracks and moisture


(D) Cut short



30. A multimeter is used for:

(A) Measuring voltage, current, and resistance


(B) Measuring only voltage


(C) Measuring only current


(D) Measuring insulation only



31. Proper labeling of electrical equipment helps to:

(A) Avoid mistakes during maintenance


(B) Increase load


(C) Reduce voltage


(D) Step up current



32. Faulty capacitors in equipment can cause:

(A) Overvoltage only


(B) Reduced power factor and heating


(C) Reduced current only


(D) Frequency drop only



33. Safety during maintenance requires:

(A) Isolation of equipment and use of PPE


(B) Only tools


(C) Only voltage measurement


(D) No safety precautions



34. Energy meters should be maintained by:

(A) Painting only


(B) Rewiring only


(C) Changing rating


(D) Periodic calibration



35. Thermistors or temperature sensors in motors are used to:

(A) Detect overheating


(B) Measure voltage


(C) Measure frequency


(D) Measure resistance



36. Cleaning of switchgear prevents:

(A) Voltage drop


(B) Overload only


(C) Arcing and insulation breakdown


(D) Frequency variation



37. Brushes in AC commutator machines should be:

(A) Properly seated and replaced if worn


(B) Loose


(C) Removed


(D) Painted



38. Thermal imaging cameras detect:

(A) Hot spots and overheating connections


(B) Voltage


(C) Frequency


(D) Current only



39. Protective earth connections are important to:

(A) Improve load factor


(B) Reduce voltage


(C) Increase frequency


(D) Prevent electric shock



40. Tightening of terminals prevents:

(A) Overheating and voltage drop


(B) Overvoltage


(C) Reduced frequency


(D) Low power factor



41. Motor winding resistance measurement helps to detect:

(A) Open or shorted turns


(B) Voltage rise


(C) Frequency drop


(D) Power factor



42. A regular maintenance schedule improves:

(A) Equipment reliability and safety


(B) Voltage only


(C) Frequency only


(D) Load only



43. DC motor armature should be checked for:

(A) Current only


(B) Voltage only


(C) Shorts, opens, and commutator condition


(D) Load only



44. Transformer oil should be filtered to remove:

(A) Moisture and impurities


(B) Voltage only


(C) Load only


(D) Current only



45. Overvoltage in motors can cause:

(A) Insulation failure


(B) Low power factor


(C) Low voltage


(D) Reduced load only



46. Loose connections in electrical panels can lead to:

(A) Reduced voltage only


(B) Sparking and overheating


(C) Frequency variation


(D) None



47. Maintenance of emergency lighting ensures:

(A) Proper operation during power failure


(B) Reduced voltage


(C) Reduced frequency


(D) Overload protection



48. Equipment maintenance records help to:

(A) Reduce voltage


(B) Increase load


(C) Track history and plan preventive maintenance


(D) Reduce frequency



49. Insulation testing should be done:

(A) Before commissioning and periodically


(B) Only after faults


(C) Randomly


(D) Only during breakdown



50. A safety switch is used to:

(A) Reduce current


(B) Increase voltage


(C) Disconnect equipment during maintenance


(D) Measure load