1. Internal resistance of an ampere meter is
(A) Very high
(B) Very low
(C) Medium
(D) Both b & c
2. Ampere meter is connected
(A) In parallel of the circuit
(B) In series of the load
(C) Both in series & parallel
(D) None of these
3. If an ampere meter is connected in parallel of the circuit.
(A) It will give no reading
(B) It will burn out promptly
(C) Will not burn
(D) It will give proper reading
4. Internal resistance of a volt meter is
(A) Very low
(B) Very high
(C) Medium
(D) Low
5. If a voltmeter is connected in parallel of the circuit (its range is suitable for supply voltage).
(A) It will burn promptly
(B) It will not give correct reading
(C) Both a & b
(D) It will give correct reading
6. If a voltmeter is connected in series of the load
(A) It will burn promptly
(B) It will not burn & will give correct reading
(C) None of these
(D) It will not burn but it will not give correct reading
7. Ampere turns of the coils of a moving iron voltmeter and moving coil ampere meter
(A) There is lot of difference
(B) There is no difference
(C) Not a nor b
(D) There is no ampere turns in it
8. Coil of moving iron voltmeter is made with
(A) Few turns of thick wire
(B) Few turns of thin wire
(C) Many turns of thick wire
(D) Many turns of thin wire
9. In permanent magnet moving coil instruments
(A) Both a & c
(B) One control spring is used
(C) One moving coil is used
(D) Two control springs are used
10. Coil former of PMMC instruments is made in
(A) Rectangular form made of aluminium
(B) Rectangular form made of copper
(C) Circular form made of copper
(D) Both a & b
11. Permanent magnet moving coil instruments are used on
(A) A.C Supply
(B) Both A.C & D.C Supply
(C) D.C supply
(D) All types of supply
12. Diameter of wire of coil in a Permanent magnet moving coil instruments use is
(A) 0.02 to 0.2 mm
(B) 0.02 to 0.2 cm
(C) 10 to 15 mm
(D) None of these
13. Purpose of cylindrical core in the Permanent magnet moving coil instruments is
(A) To concentrate the magnetic lines of force on coil
(B) To provide eddy current damping
(C) To prevent the instrument from getting heated up
(D) To prevent the magnetic lines of force not to strike on coil
14. This is used in Permanent magnet moving coil instruments.
(A) One moving coil and one permanent magnet
(B) One static coil and one permanent magnet
(C) One static coil and two permanent magnets
(D) One moving coil and one electro magnet
15. This is used in Permanent magnet moving coil instruments.
(A) Electro magnet
(B) Bar magnet
(C) Horse shoe magnet
(D) None of these
16. The scale of Permanent magnet moving coil instruments is
(A) Linear
(B) Non linear
(C) Square law scale
(D) Both a & c
17. The damping method used in permanent magnet moving coil instruments is
(A) Fluid friction method
(B) Eddy current method
(C) Air friction method
(D) Both a & c
18. Permanent magnet moving coil instruments have
(A) Medium torque to weight ratio
(B) Low torque to weight ratio
(C) High torque to weight ratio
(D) None of these
19. Permanent magnet moving coil instruments use power
(A) 25 to 50 mW
(B) 25 to 200 μW
(C) 50 to 100 mW
(D) 0.1 to 0.5 μW
20. The over load capacity of permanent magnet moving coil instruments is
(A) Very high
(B) High
(C) Low
(D) Medium
21. The length of scale of permanent magnet moving coil instruments is
(A) Up to 300°
(B) Up to 360°
(C) Up to 100°
(D) Up to 50°
22. This error does not occur in permanent magnet moving coil instruments.
(A) Frictional error
(B) Error due to thermoelectric e.m.f
(C) Error due to change in frequency
(D) Error due to stray magnetic field
23. Dynamometer type instruments are basically
(A) Moving iron type
(B) Induction type
(C) Thermal type
(D) Moving coil type
24. Dynamometer type instruments are used on
(A) Both AC & DC supply
(B) DC supply
(C) AC supply
(D) Rectified AC supply
25. Scale of dynamometer type instruments have
(A) Separate scale for AC and DC supply
(B) Same scale for AC and DC supply
(C) Supply
(D) Scale for AC supply
26. Cores of fixed and moving coils of dynamometer type instruments are made air core to
(A) To avoid iron loss
(B) To reduce the weight of the instrument
(C) Both a & b
(D) None of the above
27. The number of moving coils used in dynamometer type instruments
(A) One
(B) Two
(C) Three
(D) Four
28. Are called “transfer” instruments because
(A) They transfer power to the circuit
(B) Use only one scale for AC and DC supply
(C) They transfer measured quantity to other instruments
(D) They can easily be transferred to other type of instruments
29. These instruments give true reading even on the non sinusoidal wave form of AC supply
(A) None of these
(B) Rectifier type instruments
(C) Both a & b
(D) Dynamometer type instruments
30. Dynamometer type instruments usually have
(A) Two fix and two moving coils
(B) Two fix and one moving coil
(C) One fix and one moving coil
(D) One fix and two moving coils