T4Tutorials .PK

BUILDING DRAWING MCQs

1. F.A.R stands for:

(A) Floor Area Ratio


(B) Far Away Residence


(C) Fire Awareness Ratio


(D) None of these




2. A building meant for use as offices by a diplomatic mission:

(A) Embassy


(B) Diplomatic


(C) Chancery


(D) All of these




3. Height of Mumty (Stair Tower) may be constructed up to 10'-0" in:

(A) Commercial building


(B) Industrial building


(C) None of these


(D) Residential building




4. Fine imposed for demolition without approval for 200 sq yard plot (first floor, each attached side):

(A) Rs. 50000


(B) Rs. 75000


(C) Rs. 100000


(D) Rs. 150000




5. Fine imposed for demolition without approval for 200 sq yard plot (ground floor, each attached side):

(A) Rs. 75000


(B) Rs. 50000


(C) Rs. 100000


(D) Rs. 150000




6. Covered area for Punjab Govt. residential building for BS-20 single storey:

(A) 1300 sft


(B) 3150 sft


(C) 1650 sft


(D) 4678 sft




7. Covered area for Punjab Govt. residential building for BS-15 single storey:

(A) 4678 sft


(B) 1650 sft


(C) 3150 sft


(D) 1300 sft




8. This fixture is included in sanitary fixtures:

(A) All of these


(B) Sink


(C) Water closet


(D) Bath tub




9. This fixture is not included in sanitary fixtures:

(A) Bath tub


(B) Fountain


(C) Water closet


(D) Sink




10. Normal margin for binding side of sheet is:

(A) 0.25 inch


(B) 1.0 inch


(C) 0.75 inch


(D) 0.5 inch




11. Width of verandah for A class house is normally:

(A) 15 ft


(B) 8 ft


(C) 10 ft


(D) 12 ft




12. Top level of window should be:

(A) Top level of door


(B) 6.0 feet


(C) 5.0 feet


(D) 7.0 feet




13. A plan in which outer shape of object is shown in relation to direction or boundaries:

(A) Foundation plan


(B) Landscape plan


(C) Site plan


(D) Line plan




14. Backside view of the building is known as:

(A) Elevation


(B) Rear elevation


(C) Frontal


(D) None of these




15. Height of plinth for residential building normally is:

(A) 60 cm


(B) 30 cm


(C) 45 cm


(D) 75 cm




16. Doors of rooms should be fixed at least at a distance from corners:

(A) 4.5 inches


(B) 6 inches


(C) 7.5 inches


(D) 9 inches




17. Building used for religious purposes:

(A) All of these


(B) Temple


(C) Church


(D) Mosque




18. Width of ventilator should equal to:

(A) Window


(B) Door


(C) Ventilator


(D) Sill




19. Sill may not be provided in:

(A) Window


(B) Ventilator


(C) All of these


(D) Doors




20. Size of “A-type plots” according to Housing Department should be:

(A) 700 sq.m


(B) 1200 sq.m


(C) 1000 sq.m


(D) 1500 sq.m




Exit mobile version